    Laboratory Atomization Pilot Unit Specification

    • Industrial instrumentation
    • Made of AISI 316L stainless steel and borosilicate glass
    • Rigid process tubing

    Principle

    • Drying by atomization consists feeding the liquid to dehydrate in a form of a thin spray to obtain a powdery solid.
    • The solution is injected through an atomisation nozzle, which produce a spray made of very little drops.
    • A very hot air flow evaporates the solvent and carries away the solid powder into a cyclone.
    • The cyclone separates the solid particles from the drying airflow, which goes back outside the pilot unit.
    • The solid is collected at the base of the cyclone in a glass receiver.

    Teaching Objectives of Laboratory Atomization

    Laboratory Atomization manufacturers Experimental possibilities :

    • Atomization of a solution.
    • Influence of the drying air temperature.
    • Influence of the drying air flow rate.
    • Influence of the atomisation air flow rate.
    • Influence of the solution feeding flow rate.

    Calculations :

    • Thermal balance.
    • Mass balance.

    Technical specifications

    Equipment:

    • Feed solution glass flask.
    • Feed solution variable flow rate peristaltic pump.
    • Drying air variable flow rate centrifugal fan, made of steel.
    • Drying hot air tunnel made of AISI 304L stainless steel equipped with a variable power heating resistance.
    • Atomization tower made of borosilicate glass with glass flask receiver.
    • Atomization nozzle with air feeding and jet pump cleaning system using cyclic air.
    • Air – solid separation using a borosilicate glass cyclone with glass flask receiver.
    • Outside pilot unit air duct.

    Instrumentation :

    • Feeding air flow rate (located at the cold part) using the differential pressure measurement of an orifice plate and an electronic transducer.
      Atomization air flow rate measurement using a float type flow meter and its adjustment needle valve (nozzle air feeding).
    • Jet pump cleaning solenoid valve of the atomization nozzle.
    • Temperature safety switch of the air heating resistance.

    Electric cabinet including :

    • Drying air flow rate indicator.
    • Atomization tower temperature indicator using Pt100 Ω type sensor.
    • Drying air temperature controller.
    • Drying air fan variable speed driver.
    • Solution feeding pump variable speed driver.
    • Jet pump cleaning electronic timer of the atomization nozzle.

    Option :

    • Two relative humidity measurement probes of the drying air inlet and outlet with two channel indicator.

    Dimensions and weight

    • 1.95 m x 0.7 m x 2.6 m ~ 150 kg.

    Essential requirements

    • 400 V / 50 Hz / Three-phase:8 kW.
    • Compressed air, 6 bar:5 Nm3/h
    • Vent system.